Eltako MFZ12DDX-UC, 8 - 230, 2000 VA, 10 A, Blå
FBAC4895-B52C-4E03-B099-A6A8F8B8017B Created with sketchtool. 706D6907-81E1-46A2-B8F9-7B702A1EF2C7 Created with sketchtool. 6A870209-E7F5-44F5-A66F-09E20C85A0DC Created with sketchtool. 0BB04D6C-A9AB-4913-BF4F-5A23954E68E1 Created with sketchtool. 501E26C7-66C1-4DAA-B740-6CFAF55A1B39 Created with sketchtool. C105F7D3-D5EE-43C9-9EE8-05CC42B296D4 Created with sketchtool. D94689D8-7CBB-41C8-AC06-F79D81FF82D5 Created with sketchtool. DA4C7ED9-2512-4D52-94F0-92800F2A6E04 Created with sketchtool. 42E133FD-828F-4CF4-A0BF-560014487A57 Created with sketchtool. F52D9745-4BFD-4506-BEEF-630FD09EF2D9 Created with sketchtool.
Externen Lager (2-3 Werktage)
Das Produkt befindet sich in einem externen Lager. Die Lieferfrist: ca. 3-4 Werktage. Mehr Info

Kostenloser Versand - DHL PaketShop

Alle Möglichkeiten zeigen
Versand mit DHL - PaketShopKostenlos
Versand mit DHL zur AdresseKostenlos
Versand mit GLS - PaketShopKostenlos
Versand mit GLS zur AdresseKostenlos
EUR 121,76
ex. MwSt. 102,32
Gesamtbetrag inkl. Versand. 121,76
1 CO contact potential free 10 A/250 V AC. Incandescent lamps 2000 W.
Standby loss 0.05–0.5 watt only.
Modular device for DIN-EN 60715 TH35 rail mounting.
1 module = 18 mm wide, 58 mm deep.
With the patented Eltako Duplex technology (DX) the normally potential-free contacts can
still switch in zero passage when switching 230 V AC 50 Hz and therefore drastically reduce
wear. Simply connect the neutral conductor to the terminal (N) and L to 15 (L) for this.
This gives an additional standby consumption of only 0.1 Watt.
Universal control voltage 8 to 230 V UC. Supply voltage same as the control voltage. Both functions and times are entered at the touch of a key and indicated digitally on an LC
display. Only two keys are required for this purpose.
When setting the time all values can be entered within preset time ranges (0.1 to 9.9 or 1 to 99 seconds, minutes or hours). The longest possible setting is 99 hours. 600 settings are
possible. The time setting is continuously displayed digitally.
By using a bistable relay coil power loss and heating is avoided even in the on mode.